Does Vibrant's Tickborne Test use Western blot or ELISA? If not, what technology is used?

No, Vibrant does not use Western blot or ELISA technology.

 

Vibrant’s Lyme testing combines both indirect methods (IgG and IgM detection via an immunochip and multiplexed chemiluminescence immunoassay) and direct methods (real-time PCR using probe-based qPCR). This dual approach maximizes the detection of Borrelia species and co-infections across multiple antigen types and genetic targets, improving sensitivity and specificity.

 